For store development, design & construction

Spec Drain Protection Into Every Store

One prototype decision equals hundreds of installs. A permanent, certified sink screen removes breakroom drain callbacks from the punch list and from the maintenance budget that follows handover.

A major retailer with 1,900+ stores and distribution centers ran an 8-store pilot, then made SemperScreen® a company renovation standard with rollout through 2027/2028. The product is spec-ready under CSI MasterFormat Division 22 42 16.16.

The precedent

From pilot to prototype standard

8-store pilot where it began
Renovation standard adopted company-wide
2027/2028 rollout running through
60+ locations supplied and counting

“I really appreciate what your product has done for the sites it is installed in—it’s impressive work.”

Master Plumber
Major Retailer with 1,900+ stores

What goes in the spec package

Everything a prototype or substitution review asks for, in the format it asks for it.

CSI MasterFormatDivision 22 42 16.16
CertificationASME A112.18.2-2020 / CSA B125.2-20
MaterialPolished stainless (304 stainless steel), brushed trim ring
ConstructionProprietary double-walled technology; perforation surface area exceeds the connecting pipe
FitsStandard 3½" drains; custom tube nut for 1-1/2" tailpiece
Install~15 minutes per drain, retrofit, no plumbing modifications
Warranty5-year commercial warranty on B2B installations

Fitting a rollout

It has to survive the schedule, not just the spec

No trade coordination

Retrofit into the existing drain assembly with no plumbing modifications, so it does not add a plumbing scope item or a permit conversation to the package.

Fits the remodel window

~15 minutes per drain means a store's breakroom is done inside a normal fit-out day rather than pulling a crew back for a return visit.

Nothing to service after handover

No moving parts and nothing to replace, so it does not create a recurring line in the facilities budget the moment the store opens.

One SKU across the fleet

A standard 3½" drain is a standard 3½" drain, so the same specification carries across prototypes, remodels, and existing stores.

Certified performance

Certified test data for the submittal

Certified test data in the form a prototype or substitution review asks for. Measured values against the clause requirement, with the margin shown.

TestedStandard requiresMeasured
Flow rate≥ 7.0 gpm @ 6" head> 11.0 gpm — 57% above minimum
Screen aperture≤ 0.2 in (5 mm)0.08 in (2.0 mm) — 2.5× finer
Body wall thickness≥ 0.022 in (0.56 mm)0.029 in (0.74 mm) — 1.32×
Screen thickness≥ 0.015 in (0.38 mm)0.023 in (0.58 mm) — 1.53×
Thermal cycling7 cycles, 180 °F ↔ 70 °FNo cracking, leaking, or deformation
Hydrostatic pressure5.0 psi, 1 minNo leakage, cracking, or deformation
Seals leakage20 in (500 mm) column, 5 minNo leakage
Material300/400 series stainlessType 304 stainless steel
Outlet size1½ in nominal OD
Outlet thread1½–11½ NPSM, ASME B1.20.1Conforms
Thread torque strength20 N·m (15 ft·lbf)No stripping or thread damage
CorrosionASTM B117 neutral salt SC-2≤1 defect/in²; none > 0.03 in
ServiceabilityStandard toolsServiceable with adjustable wrench
MarkingsPermanent, visible after install"SEMPERSCREEN" permanently marked

Catalog dimensions

Install size 3½ in (88.9 mm) · install depth 2.8 in (71 mm) · tailpiece 1½ in cut threads · weight 1 lb (0.45 kg) · proprietary double-wall construction, polished screen.

What goes in the submittal

CSI MasterFormat Division 22 42 16.16, the certified performance table above, catalog dimensions, and the standard-tool serviceability finding that substitution reviews ask about.

Tested and COMPLIED with ASME A112.18.2-2020 / CSA B125.2-20.Screen permanently fixed to the body and not removable by occupants; the assembly installs and services with standard tools.

Program ROI calculator

What Do Breakroom Drain Callbacks Cost the Fleet?

Enter your program numbers. See the annual drain cost across the estate and what the SemperScreen® permanent sink screen eliminates.

Drain Maintenance Cost Calculator

Estimates based on your inputs.

Annual Drain Cost
SemperScreen® Portfolio Cost (installed)
Estimated First-Year Savings

Request a Sample Kit →

* Estimates savings against recurring drain service calls. Sewage ejector failure risk ($3,000–$15,000+ per event) is not included. Product plus installation estimate based on standard portfolio pricing.

The case on paper

Why a Screen Beats a Policy

An engineering control, not a training program

NIOSH ranks engineering controls above administrative controls because they work without significant human interaction. Its criteria for a good engineering control include blocking the hazard at the source, needing minimal user action, and preventing users from interfering with the control.

By that federal definition, a drain control any person can defeat in two seconds sits in a lower category. The guidance side proves the point by accident: a state FOG best-practices document instructs operators to train kitchen staff not to remove drain screens, then concedes that success depends on the behavior of the employee. Another jurisdiction reproduced the instruction unchanged eighteen years later.

Grinding does not remove anything

A disposal changes particle size. It removes nothing from the waste stream, and macerated particles give grease more surface area to bind to. EPA identified grease as the most common cause of reported blockages at 47 percent, and 40 CFR 403.5(b)(3) prohibits discharging solids in amounts that will cause obstruction in the collection system.

Princeton, New Jersey bars mechanical garbage disposal waste from multi-family dwellings of three or more units except by written permission of the sewer engineer, and codifies drain screens as a required best management practice. Tahoe City Public Utility District bars commercial disposals from the public sewer and directs that screens be installed in all sinks receiving food waste.

SemperScreen® recommends that you always refer to local building codes when modifying a building’s plumbing system. Requirements vary by jurisdiction.

What the code actually asks of the pump

IPC 712.4.2 states what a pump must be capable of passing. It sets no limit on upstream screening, and the threshold tightened between editions.

Pump type and code editionRequired capability
Receives water closet discharge, all editions2 in (51 mm)
Other pumps and ejectors, IPC 2012–20181 in (25.4 mm)
Other pumps and ejectors, IPC 2021, 20241/2 in (13 mm)
Certified screen aperture0.08 in (2.0 mm)

A 0.08 in aperture is roughly six times finer than the largest particle the current code contemplates.

Sources EPA National Pretreatment Program · NIOSH Hierarchy of Controls, CDC · NC Department of Environment and Natural Resources, FOG Best Management Practices · Borough of Kennett Square, PA, FOG Best Practices · Municipality of Princeton, NJ § B34-22 and § B34-23 · Tahoe City Public Utility District Sewer FAQs · IPC 712.4.2.

One SKU

One SKU, every store format

Fits standard commercial sink drains One SKU. Every store format. Every standard sink install.

Spec review

Put it in front of the prototype team

Sample kit ships free. No purchase commitment.

Sizes the pilot and the spec package.

Sends your request and opens the calendar so you can pick a time.

How a spec-in starts

  1. Sample kit to the prototype team, no commitment.
  2. A pilot at a handful of stores, scoped to your remodel schedule.
  3. Spec language and volume pricing for the prototype package.

Already have a distributor on the program? They can stock it by part number (call about specific distributors not listed).

DistributorPart Number
HJC/Hajoca#2225843
Ferguson#4923243
Reece#2263774
Grainger#45194490
General Plumbing SupplyCall
WinsupplyCall
CWH#03203
Best Plumbing#99881382
Hirsch Pipe & Supply#6426627

Find a SemperScreen® Dealer

What store development asks

New to the product? See how it works, or the properties and facilities overview.